Troubleshooting Common Circulation Pump Problems and How to Fix Them

Troubleshooting Common Circulation Pump Problems and How to Fix Them

With regards to the home's outdoor wood boiler system, one of the most important components is the circulation pump and it is used for circulating water used for heating purposes. Having a good working circulation pump is important if you want the heat from your boiler to circulate through your building or outbuildings. However, being mechanical devices, circulation pumps might be encountered with problems from time to time. Here are the tricks of how to overcome typical circulation pump issues and necessary repair for the best circulator pump for your boiler.

1. Pump Won’t Start

If the circulation pump won’t start, it may not be a complicated issue at all: a fuse may have blown, circuit has been tripped or there might be a problem with the power supply. First of all it is necessary to investigate the power supply to ascertain that all cables are properly connected. If the problem remains, then diagnose the motor and look for some visible signs of its deterioration or wear out. If it is an outdoor wood boiler circulator pump, then check whether moisture or any dirt affected the wiring system.

Pump

2. Pump Making Strange Noises

Any unusual grinding or rattling sound from a circulation pump could be due to trapped air, worn bearings or debris clogging within the pump. To fix this, it is recommended to bleed the pump so that the bubbles in the system can be brought to the surface. If the noise persists one should check the pump for parts that should be removed for a tight fit to reduce the noise production. A damaged bearing of a pump will call for replacement of the same. If a replacement is needed for your boiler, then take time to ensure that you have the right circulator pump for your boiler.

3. Pump Not Circulating Water Efficiently

If your water circulation pump isn’t circulating water efficiently then the problem lies in the pipes or the partially blocked impeller. There are circumstances where the mineral deposits, or deposits can hinder water circulation. For this, it is right to clean the pump and any pipe that is associated with it.Such clogs are easily avoidable by practicing maintenance on your system such as occasionally flushing your system. Further, ensure the circulation pump for the boiler is in the right size for the system that you have.

4. Pump Running but No Heat Transfer

If there is active circulation of water by the circulation pump but there is no heat transfer then the problem may be with the settings of the pump or there may be blockage in water flow somewhere in the loop. The first thing to do is to ensure that the thermostat and pump settings are what they should be. If all seems to be well in terms of installation, there could be some blocks that are preventing air flow within the pipelines. An outdoor wood boiler circulator pump may accumulate debris in its lines or could freeze during harsh winters; therefore, you need to insulate your lines.

5. Pump Running Continuously

If your circulation pump is always running even when the boiler is not in the process of heating, then the circulation pump might be on a defective thermostat, pump relay or wiring problem. In addition, look at the thermostat and examine the relay for signs of its inefficiency in the process. If it is beyond yours or anyone else’s understanding, go seek the services of a technician, so you can know where to fix the issue with the electrical components. Sometimes the thermostat of the hot tub is actually causing the pump to run continuously, which is just very inefficient and shortens the life of your circulation pump.

Conclusion

Circulation pump issues do not have to be complex in handling as is explained above. If you understand the most common problems and know how to address them, you can keep your boiler system running smoothly for years without breakdowns.

Outdoor Logo

Regardless of whether your outdoor wood boiler has stopped working due to a faulty circulator pump or another issue, identifying the root cause is essential for restoring its functionality, it is possible that you need to alter or fix the circulation pump for your boiler and these few tips could be very useful to ensure every component is well maintained and in good condition. When you are in need of a replacement always get the best circulator pump from Outdoor Boiler for the boiler if you want to achieve the best heating outcomes.